Adsorption by Activated ...
Published by Rajendrakumar Saraf
Adsorption by Activated Carbon (AC) depends on Iodine Value and the contact time between AC and water. There is no mathematical relationship between height of AC bed and concentration of organic matter. pH & temperature plays very important role. It is higher at lower temperature & pH level. I always ensure to have bed height around 1 M and surface loading rate 15 to 20 m3/m2/hr. This ensure maximum contact time with AC. For details please contact on rvsceipl@gmail.com
1 Comment
Hi Raj, please not that there is a messaging functionality inside The Water Network. easier to connect then you can message mohamed zakaria elhanafy on the platform instead of relying on emails
Published by Trudi Schifter, CEO and Founder AquaSPE
1 Comment
Hi
Thanks. I was not aware of this.
Published by Rajendrakumar Saraf