Get ground SHMP, a ...
Published by Terry Scheurman, President at Applied Specialties, Inc.
Get ground SHMP, a volumetric feeder and a high shear pump. Introduce the SHMP into the suction side of the pump with a volumetric dry screw feeder. Option 2 buy a 38% solution and dilute it locally.
Adding large amounts of SHMP into a tank gets you SHMP gunk on the bottom of the tank that takes a long time to dissolve. You want to increase the surface area of the SHMP to the water.